Facility & Technology

World-class infrastructure designed for hyperscale operations

Infrastructure Overview

The Sacheon HyperCloud Data Campus features state-of-the-art infrastructure designed to support the most demanding hyperscale and AI workloads.

Our facility combines cutting-edge power systems, advanced cooling technology, and robust network connectivity to deliver unparalleled performance and reliability.

300MW
Total Power Capacity
1.25
Target PUE
99.995%
Uptime SLA
24/7
Support

Power Infrastructure

Reliable Power Systems

345kV Dual Grid Connection

Redundant power feeds from separate utility substations ensure maximum reliability

2N Redundancy

Fully redundant UPS and generator systems with N+1 configuration

Scalable to 300MW

Modular design allows for seamless capacity expansion as demand grows

Power Infrastructure

Power Distribution

State-of-the-art electrical infrastructure designed for maximum efficiency and reliability

Advanced Cooling Systems

Hybrid Air/Liquid Cooling

Optimized cooling solution combining air and liquid cooling for maximum efficiency

  • • Free air cooling systems
  • • Direct liquid cooling for high-density racks
  • • AI-optimized temperature control

Energy Efficiency

Industry-leading PUE 1.25 target through innovative design

  • • Smart grid integration
  • • Real-time energy monitoring
  • • Waste heat recovery systems

Intelligent Controls

AI-driven environmental management for optimal performance

  • • Predictive maintenance
  • • Automated load balancing
  • • Real-time optimization

Network Connectivity

Strategic positioning on major Asia-Pacific subsea cable routes provides unparalleled global connectivity with ultra-low latency to key markets.

Asia-Pacific Submarine Cable Network

Busan-Geoje-Sacheon Subsea Cable Network

<15ms
Tokyo
Ultra-low latency
<25ms
Hong Kong
Financial hub access
<35ms
Singapore
ASEAN gateway
<20ms
Shanghai
China market access

Security & Compliance

Physical Security

24/7 security, biometric access, CCTV monitoring

24/7 Monitoring

Real-time infrastructure monitoring and alerts

Compliance

ISO 27001, SOC 2 certification compliance

Technical Support

On-site support from expert engineers

Resilience & Safety

Seismic & Flood Protection

Seismic compliance per local code

Flood-safe elevation design

Infrastructure Redundancy

Multi-path fiber across campus

Dual power feeds for reliability

Technical Specifications

Power Density

Standard Racks:5-10kW
High Density:20-30kW
AI/HPC:50kW+

Cooling Capacity

Air Cooling:15kW/rack
Liquid Cooling:50kW/rack
Target PUE:1.25

Connectivity

Fiber Capacity:Multi-Tbps
Cross Connects:Available
Cloud On-ramps:Direct

Experience World-Class Infrastructure

Schedule a tour of our state-of-the-art facilities

Talk with Us